Skip to main content

UL508, Non-Fused (LBSM Series - Front Operated)

The UL508, Non-Fused (LBSM Series - Front Operated) is part of the Mersen (formerly Ferraz Shawmut) disconnect switches line, distributed by Gross Automation.

UL508, Non-Fused (LBSM Series - Front Operated)

Ferraz Shawmut LBS load break disconnect switches have been designed for today's industrial control systems. The LBS switches allow you to safely turn power to your panel on and off or to isolate a particular circuit within the panel. These switches are extremely compact and offer a variety of mounting options like DIN rail mounting, base mounting, or door mounting. A wide assortment of handles, shafts and accessories are available to provide you with the ultimate flexibility in the design of your industrial control panels. Wiring terminations are integral to the switch body and recessed to insure a "finger safe" environment according to IEC standards to an IP20 grade of protection.

Specifications

SpecificationValue
RatingsAC: 600VAC, 16, 20, 25, 30, 40, 60, 80, 100, and 125 amperes; Meets the requirements of UL 508; UL Listed, Guide NLRV, File E196672; cUL Listed, Guide NLRV7, File E196672; CSA Certified; IEC 947-3 as load break disconnector; On/Off switching and disconnect applications in circuits up to 600 volts, 125 amperes on the load side of branch circuit protection fusing.; LMB M range: Motor Controller; LBS R range: Motor Controller Suitable as Motor Disconnect; Motor Isolator; General Purpose;
FeaturesFinger Safe; Compact footprint; DIN rail or base mount standard; Door mounting optional; Choice of external handles/shafts; Direct mount handle option; Toggle handle option

Features

  • Finger Safe
  • Compact footprint
  • DIN rail or base mount standard
  • Door mounting optional
  • Choice of external handles/shafts
  • Direct mount handle option
  • Toggle handle option

Ratings

  • AC: 600VAC, 16, 20, 25, 30, 40, 60, 80, 100, and 125 amperes
  • Meets the requirements of UL 508
  • UL Listed, Guide NLRV, File E196672
  • cUL Listed, Guide NLRV7, File E196672
  • CSA Certified
  • IEC 947-3 as load break disconnector
  • On/Off switching and disconnect applications in circuits up to 600 volts, 125 amperes on the load side of branch circuit protection fusing.
  • LMB M range: Motor Controller
  • LBS R range: Motor Controller Suitable as Motor Disconnect
  • Motor Isolator
  • General Purpose

Documentation