Specifications

SpecificationValue
FeaturesFinger Safe; Compact footprint; Internal bridging link provided as standard; Fully visualized breaking; Large number of mounting possibilities (DIN rail, backplate or door mounting); Large number of configurations (I-II, I-0-II, I-0-II by-pass, I-I+II-II); Choice of external and direct handles

Features

  • Finger Safe
  • Compact footprint
  • Internal bridging link provided as standard
  • Fully visualized breaking
  • Large number of mounting possibilities (DIN rail, backplate or door mounting)
  • Large number of configurations (I-II, I-0-II, I-0-II by-pass, I-I+II-II)
  • Choice of external and direct handles

Ratings

  • AC: 25 to 125 Amperes
  • UL508 Manual / Motor Controller (25, 40, 63, 80, 100, 125 A)
  • IEC 60947-3
  • NF EN 60947-3
  • VDE 0660 Teil 107 (1992)
  • Manual changeover from main supply to back-up source
  • Switching between loads (motor or back-up)
  • Reversing motor via phase inversion
  • By-pass (upstream and downstream isolation in one operation)
  • Earthing switch

Catalog Numbers

Select a Switch

OperationPolesAmpere RatingCatalog Number
I-II325 A4220 3002+
I-II340 A4220 3004+
I-II363 A4220 3006+
I-II425 A4220 4002+
I-II440 A4220 4004+
I-II463 A4220 4006+
I-0-II325 A4230 3002+
I-0-II340 A4230 3004+
I-0-II363 A4230 3006+
I-0-II425 A4230 4002+
I-0-II440 A4230 4004+
I-0-II463 A4230 4006+
I-0-II by-pass3+625 A4250 3002+
I-0-II by-pass3+640 A4250 3004+
I-0-II by-pass3+663 A4250 3006+
I-0-II by-pass4+825 A4250 4002+
I-0-II by-pass4+840 A4250 4004+
I-0-II by-pass4+863 A4250 4006+
I-I+II-II (overlapping)325 A4240 3002+
I-I+II-II (overlapping)340 A4240 3004+
I-I+II-II (overlapping)363 A4240 3006+
I-I+II-II (overlapping)425 A4240 4002+
I-I+II-II (overlapping)440 A4240 4004+
I-I+II-II (overlapping)463 A4240 4006+
I-0-II with one auxiliary contact325 A4230 3102+
I-0-II with one auxiliary contact340 A4230 3104+
I-0-II with one auxiliary contact363 A4230 3106+
I-0-II with one auxiliary contact425 A4230 4102+
I-0-II with one auxiliary contact440 A4230 4104+
I-0-II with one auxiliary contact463 A4230 4106+
I-0-II with two auxiliary contacts325 A4230 3202+
I-0-II with two auxiliary contacts340 A4230 3204+
I-0-II with two auxiliary contacts363 A4230 3206+
I-0-II with two auxiliary contacts425 A4230 4202+
I-0-II with two auxiliary contacts440 A4230 4204+
I-0-II with two auxiliary contacts463 A4230 4206+
I-II380 A4220 3008+
I-II3100 A4220 3010+
I-II3125 A4220 3012+
I-II480 A4220 4008+
I-II4100 A4220 4010+
I-II4125 A4220 4012+
I-0-II380 A4230 3008+
I-0-II3100 A4230 3010+
I-0-II3125 A4230 3012+
I-0-II480 A4230 4008+
I-0-II4100 A4230 4010+
I-0-II4125 A4230 4012+
I-0-II by-pass3+680 A4250 3008+
I-0-II by-pass3+6100 A4250 3010+
I-0-II by-pass3+6125 A4250 3012+
I-0-II by-pass4+880 A4250 4008+
I-0-II by-pass4+8100 A4250 4010+
I-0-II by-pass4+8125 A4250 4012+
I-I+II-II (overlapping)380 A4240 3008+
I-I+II-II (overlapping)3100 A4240 3010+
I-I+II-II (overlapping)3125 A4240 3012+
I-I+II-II (overlapping)480 A4240 4008+
I-I+II-II (overlapping)4100 A4240 4010+
I-I+II-II (overlapping)4125 A4240 4012+
I-0-II with one auxiliary contact380 A4230 3108+
I-0-II with one auxiliary contact480 A4230 4108+
I-0-II with two auxiliary contacts380 A4230 3208+
I-0-II with two auxiliary contacts480 A4230 4208+

Select a Handle

OperationTo Suit SwitchPadlock PositionIP RatingColorAmpere RatingCatalog Number
External and direct operationI-III-IIIP54Black/Grey25 A, 40 A4259 1042+
External and direct operationI-III-IIIP54Black/Grey63 A4259 1082+
External and direct operationI-III-IIIP54Red/Yellow25 A, 40 A4259 1043+
External and direct operationI-III-IIIP54Red/Yellow63 A4259 1083+
External and direct operationI-0-II / By-pass0IP54Black/Grey25 A, 40 A4259 1042+
External and direct operationI-0-II / By-pass0IP54Black/Grey63 A4259 1082+
External and direct operationI-0-II / By-pass0IP54Red/Yellow25 A, 40 A4259 1043+
External and direct operationI-0-II / By-pass0IP54Red/Yellow63 A4259 1083+
External and direct operationI-I+II-III-I+II-IIIP54Black/Grey25 A, 40 A4259 1042+
External and direct operationI-I+II-III-I+II-IIIP54Black/Grey63 A4259 1082+
External and direct operationI-I+II-III-I+II-IIIP54Red/Yellow25 A, 40 A4259 1043+
External and direct operationI-I+II-III-I+II-IIIP54Red/Yellow63 A4259 1083+
External and direct operationI-II—IP54White25 A4259 2022+
External and direct operationI-II—IP54White40 A4259 2042+
External and direct operationI-II—IP54White63 A4259 2082+
External and direct operationI-0-II / By-pass—IP54White25 A4259 3022+
External and direct operationI-0-II / By-pass—IP54White40 A4259 3042+
External and direct operationI-0-II / By-pass—IP54White63 A4259 3082+
External and direct operationI-I+II-II—IP54White25 A4259 4022+
External and direct operationI-I+II-II—IP54White40 A4259 4042+
External and direct operationI-I+II-II—IP54White63 A4259 4082+
External and direct operationI-III-IIIP54Black/Grey80 A, 100 A, 125 A4259 1082+
External and direct operationI-III-IIIP54Red/Yellow80 A, 100 A, 125 A4259 1083+
External and direct operationI-0-II / By-pass0IP54Black/Grey80 A, 100 A, 125 A4259 1082+
External and direct operationI-0-II / By-pass0IP54Red/Yellow80 A, 100 A, 125 A4259 1083+
External and direct operationI-I+II-III-I+II-IIIP54Black/Grey80 A, 100 A, 125 A4259 1082+
External and direct operationI-I+II-III-I+II-IIIP54Red/Yellow80 A, 100 A, 125 A4259 1083+
External and direct operationI-II—IP54White80 A, 100 A, 125 A4259 2082+
External and direct operationI-0-II / By-pass—IP54White80 A, 100 A, 125 A4259 3082+
External and direct operationI-I+II-II—IP54White80 A, 100 A, 125 A4259 4082+

Select a Shaft

Shaft Length (inches/mm)Ampere RatingCatalog NumberNotes
7.9/20025 A, 40 A4259 5042+Includes an escutcheon allowing the function of door interlocking in ON position
7.9/20063 A4259 5082+Includes an escutcheon allowing the function of door interlocking in ON position
7.9/20080 A, 100 A, 125 A4259 5082+Includes an escutcheon allowing the function of door interlocking in ON position

Options

OptionDescriptionAmpere RatingCatalog NumberNotes
Back plate mounting device25 A, 40 A4259 9040+
Back plate mounting device63 A4259 9080+
DIN rail mounting device25 A, 40 A, 63 A4259 9001+
Back plate mounting device80 A, 100 A, 125 A4259 9080+
DIN rail mounting device80 A, 100 A, 125 A4259 9001+

Documentation