Specifications

SpecificationValue
FeaturesFully visualized breaking 3 stable positions (I-0-II or overlapping I-I+II-II)

Features

  • Fully visualized breaking 3 stable positions (I-0-II or overlapping I-I+II-II)

Ratings

  • AC: 125, 160, 200, 250, 400, 630, 800, 1250, 1600, 2000, 2500 and 3150 amperes
  • IEC 60947-3
  • NF EN 60947-3
  • VDE 0660 Teil 107 (1992)
  • NBN EN 60947-3
  • BS EN 60947-3
  • Manual changeover from main supply to back-up source
  • Switching between loads (motor or back-up)
  • Reversing motor via phase inversion
  • Earthing switch

Catalog Numbers

Select a Switch

OperationPolesAmpere RatingCatalog Number
I-0-II3CD 125A4100 3013+
I-0-II3CD 160A4100 3016+
I-0-II3CD 200A4100 3019+
I-0-II4CD 125A4100 4013+
I-0-II4CD 160A4100 4016+
I-0-II4CD 200A4100 4019+
I-I+II-II (overlapping)3CD 125A4190 3013+
I-I+II-II (overlapping)3CD 160A4190 3016+
I-I+II-II (overlapping)3CD 200A4190 3019+
I-I+II-II (overlapping)4CD 125A4190 4013+
I-I+II-II (overlapping)4CD 160A4190 4016+
I-I+II-II (overlapping)4CD 200A4190 4019+
I-0-II3CD 250A4100 3025+
I-0-II3CD 400A4100 3039+
I-0-II3CD 630A4100 3063+
I-0-II4CD 250A4100 4025+
I-0-II4CD 400A4100 4039+
I-0-II4CD 630A4100 4063+
I-I+II-II (overlapping)3CD 250A4190 3025+
I-I+II-II (overlapping)3CD 400A4190 3039+
I-I+II-II (overlapping)3CD 630A4190 3063+
I-I+II-II (overlapping)4CD 250A4190 4025+
I-I+II-II (overlapping)4CD 400A4190 4039+
I-I+II-II (overlapping)4CD 630A4190 4063+
I-0-II3CD 800A4100 3080+
I-0-II3CD 1250A4100 3120+
I-0-II31600A4200 3160+
I-0-II4CD 800A4100 4080+
I-0-II4CD 1250A4100 4120+
I-0-II41600A4200 4160+
I-I+II-II (overlapping)3CD 800A4190 3080+
I-I+II-II (overlapping)3CD 1250A4190 3120+
I-I+II-II (overlapping)31600A4290 3160+
I-I+II-II (overlapping)4CD 800A4190 4080+
I-I+II-II (overlapping)4CD 1250A4190 4120+
I-I+II-II (overlapping)41600A4290 4160+
I-0-II32000A4200 3200+
I-0-II32500A4200 3250+
I-0-II33150A4200 3310+
I-0-II42000A4200 4200+
I-0-II42500A4200 4250+
I-0-II43150A4200 4310+

Select a Handle

OperationTo Suit SwitchPadlock PositionIP RatingColorAmpere RatingCatalog Number
External operationI-0-II0IP54BlackCD 125A, CD 160A, CD 200A4199 5032+
External operationI-0-II0IP65BlackCD 125A, CD 160A, CD 200A4199 5036+
External operationI-0-III-0-IIIP54BlackCD 125A, CD 160A, CD 200A4199 5015+
External operationI-0-III-0-IIIP65BlackCD 125A, CD 160A, CD 200A4199 5016+
External operationI-I+II-III+IIIP54BlackCD 125A, CD 160A, CD 200A4199 5039+
External operationI-I+II-III-I+II-IIIP54BlackCD 125A, CD 160A, CD 200A4199 5019+
External operationI-I+II-III-I+II-IIIP65BlackCD 125A, CD 160A, CD 200A4199 7016+
Direct operationI-0-II / I-I+II-III-0-II / I-I+II-II—BlackCD 125A, CD 160A, CD 200A4199 5012+
External operationI-0-II0IP54BlackCD 250A, CD 400A, CD 630A4199 5032+
External operationI-0-II0IP65BlackCD 250A, CD 400A, CD 630A4199 5036+
External operationI-0-III-0-IIIP54BlackCD 250A, CD 400A, CD 630A4199 5015+
External operationI-0-III-0-IIIP65BlackCD 250A, CD 400A, CD 630A4199 5016+
External operationI-I+II-III+IIIP54BlackCD 250A, CD 400A, CD 630A4199 5039+
External operationI-I+II-III-I+II-IIIP54BlackCD 250A, CD 400A, CD 630A4199 5019+
External operationI-I+II-III-I+II-IIIP65BlackCD 250A, CD 400A, CD 630A4199 7016+
Direct operationI-0-II / I-I+II-III-0-II / I-I+II-II—BlackCD 250A, CD 400A, CD 630A4199 5012+
External operationI-0-III-0-IIIP54BlackCD 800A, CD 1250A, 1600A4494 5125+
External operationI-I+II-III-I+II-IIIP54BlackCD 800A, CD 1250A, 1600A4494 5129+
Direct operationI-0-II / I-I+II-III-0-II / I-I+II-II—BlackCD 800A, CD 1250A, 1600A2799 7052+
External operationI-0-III-0-IIIP65Black2000A, 2500A, 3150A2799 7146+
Direct operationI-0-III-0-II—Black2000A, 2500A, 3150A2799 7012+

Select a Shaft

Shaft Length (inches/mm)Ampere RatingCatalog NumberNotes
7.9/200CD 125A, CD 160A, CD 200A3999 3004+
12.6/320CD 125A, CD 160A, CD 200A3999 3013+
7.9/200CD 250A, CD 400A, CD 630A3999 3004+
12.6/320CD 250A, CD 400A, CD 630A3999 3013+
7.9/200CD 800A, CD 1250A, 1600A2799 3015+
17.7/450CD 800A, CD 1250A, 1600A2799 3019+
12.6/3202000A, 2500A, 3150A2799 3018+

Options

OptionDescriptionAmpere RatingCatalog NumberNotes
3-pole Terminal Shrouds Kit (IP20)Line + load shroud side / front terminalsCD 125A, CD 160A, CD 200A4194 3013+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
3-pole Terminal Shrouds Kit (IP20)Line + load shroud side / rear terminalsCD 125A, CD 160A, CD 200A4195 3013+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
4-pole Terminal Shrouds Kit (IP20)Line + load shroud side / front terminalsCD 125A, CD 160A, CD 200A4194 4013+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
4-pole Terminal Shrouds Kit (IP20)Line + load shroud side / rear terminalsCD 125A, CD 160A, CD 200A4195 4013+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
Bridging barsFor 1 poleCD 125A, CD 160A, CD 200A4109 0019+One bridging bar required per pole
Auxiliary contacts1st NO.NC per position, 16ACD 125A, CD 160A, CD 200A4109 0021+
Auxiliary contacts2nd NO.NC per position, 16ACD 125A, CD 160A, CD 200A4109 0021+Mounted on the first aux. contact (part 4109 0021)
3-pole Terminal Shrouds Kit (IP20)Line + load shroud side / front terminalsCD 250A, CD 400A4194 3025+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
3-pole Terminal Shrouds Kit (IP20)Line + load shroud side / front terminalsCD 630A4194 3050+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
3-pole Terminal Shrouds Kit (IP20)Line + load shroud side / rear terminalsCD 250A, CD 400A4195 3025+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
3-pole Terminal Shrouds Kit (IP20)Line + load shroud side / rear terminalsCD 630A4195 3050+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
4-pole Terminal Shrouds Kit (IP20)Line + load shroud side / front terminalsCD 250A, CD 400A4194 4025+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
4-pole Terminal Shrouds Kit (IP20)Line + load shroud side / front terminalsCD 630A4194 4050+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
4-pole Terminal Shrouds Kit (IP20)Line + load shroud side / rear terminalsCD 250A, CD 400A4195 4025+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
4-pole Terminal Shrouds Kit (IP20)Line + load shroud side / rear terminalsCD 630A4195 4050+One shroud required for front and for back terminal, max two shrouds required; cannot fit rear terminal shroud when bridging bars are fitted
Bridging barsFor 1 poleCD 250A4109 0025+One bridging bar required per pole
Bridging barsFor 1 poleCD 400A4109 0039+One bridging bar required per pole
Bridging barsFor 1 poleCD 630A4109 0063+One bridging bar required per pole
Auxiliary contacts1st NO.NC per position, 16ACD 250A, CD 400A, CD 630A4109 0021+
Auxiliary contacts2nd NO.NC per position, 16ACD 250A, CD 400A, CD 630A4109 0021+Mounted on the first aux. contact (part 4109 0021)
3-pole Terminal ScreenLine or load side / front terminalsCD 800A, CD 1250A2998 3080+
3-pole Terminal ScreenLine or load side / front terminals1600A2998 3120+
4-pole Terminal ScreenLine or load side / front terminalsCD 800A, CD 1250A2998 4080+
4-pole Terminal ScreenLine or load side / front terminals1600A2998 4120+
Bridging barsFor 1 poleCD 800A4109 0080+One bridging bar required per pole
Bridging barsFor 1 poleCD 1250A4109 0120+One bridging bar required per pole
Bridging barsFor 1 pole1600A4409 0160+One bridging bar required per pole
Auxiliary contacts1st NO.NC per position, 16ACD 800A, CD 1250A4109 0021+
Auxiliary contacts1st NO.NC per position, 16A1600A4409 0021+
Auxiliary contacts2nd NO.NC per position, 16ACD 800A, CD 1250A4109 0021+Mounted on the first aux. contact (part 4109 0021 or 4409 0021)
Auxiliary contacts2nd NO.NC per position, 16A1600A4409 0022+Mounted on the first aux. contact (part 4109 0021 or 4409 0021)
Bridging barsFor 1 pole (factory fitted)2000A, 2500A4409 0250+One bridging bar required per pole
Bridging barsFor 1 pole (factory fitted)3150A4409 0310+One bridging bar required per pole
Auxiliary contacts1st NO.NC per position, 16A2000A, 2500A, 3150A4409 0021+
Auxiliary contacts2nd NO.NC per position, 16A2000A, 2500A, 3150A4409 0022+Mounted on the first aux. contact (part 4409 0021)