SIRCOVER BY-PASS are manually operated multipolar changeover switches. They are a combination of three interlocked switches for use with 3+6 poles or 4+8 poles. They insulate by providing simultaneous safety isolation upstream and downstream and by passing loads or low voltage circuits mainly during maintenance operations.

Specifications

SpecificationValue
FeaturesFully visualized breaking; 3 stable positions (I-0-II) or on request overlapping contacts (I-I+II-II)

Features

  • Fully visualized breaking
  • 3 stable positions (I-0-II) or on request overlapping contacts (I-I+II-II)

Ratings

  • AC: 125, 160, 200, 250, 400, 630, 800, 1250 and 1600 amperes
  • IEC 60947-3
  • NF EN 60947-3
  • VDE 0660 Teil 107 (1992)
  • NBN EN 60947-3
  • BS EN 60947-3
  • Circuit by-pass, UPS, SPEED VARIATOR

Catalog Numbers

Select a Switch

OperationPolesAmpere RatingCatalog Number
I-0-II by-pass3+6CD 125A4100 7013+
I-0-II by-pass3+6CD 160A4100 7016+
I-0-II by-pass3+6CD 200A4100 7019+
I-0-II by-pass4+8CD 125A4100 9013+
I-0-II by-pass4+8CD 160A4100 9016+
I-0-II by-pass4+8CD 200A4100 9019+
I-0-II by-pass3+6CD 250A4100 7025+
I-0-II by-pass3+6CD 400A4100 7039+
I-0-II by-pass3+6CD 630A4100 7063+
I-0-II by-pass4+8CD 250A4100 9025+
I-0-II by-pass4+8CD 400A4100 9039+
I-0-II by-pass4+8CD 630A4100 9063+
I-0-II by-pass3+6CD 800A4100 7080+
I-0-II by-pass3+6CD 1250A4100 7120+
I-0-II by-pass3+61600A4200 7160+
I-0-II by-pass4+8CD 800A4100 9080+
I-0-II by-pass4+8CD 1250A4100 9120+
I-0-II by-pass4+81600A4200 9160+

Select a Handle

OperationTo Suit SwitchPadlock PositionIP RatingColorAmpere RatingCatalog Number
External operationI-0-II By-pass0IP54BlackCD 125A, CD 160A, CD 200A4199 5032+
External operationI-0-II By-pass0IP65BlackCD 125A, CD 160A, CD 200A4199 5036+
External operationI-0-II By-passI-0-IIIP54BlackCD 125A, CD 160A, CD 200A4199 5015+
External operationI-0-II By-passI-0-IIIP65BlackCD 125A, CD 160A, CD 200A4199 5016+
Direct operationI-0-II By-passI-0-II—BlackCD 125A, CD 160A, CD 200A4199 5012+
External operationI-0-II By-passI-0-IIIP54BlackCD 250A, CD 400A, CD 630A4494 5125+
Direct operationI-0-II By-passI-0-II—BlackCD 250A, CD 400A, CD 630A2799 7052+
External operationI-0-II By-passI-0-IIIP65BlackCD 800A, CD 1250A, 1600A4199 7146+
Direct operationI-0-II By-passI-0-II—BlackCD 800A, CD 1250A, 1600A2799 7012+

Select a Shaft

Shaft Length (inches/mm)Ampere RatingCatalog NumberNotes
7.9/200CD 125A, CD 160A, CD 200A3999 3004+
12.6/320CD 125A, CD 160A, CD 200A3999 3013+
7.9/200CD 250A, CD 400A, CD 630A2799 3015+
17.7/450CD 250A, CD 400A, CD 630A2799 3019+
7.9/200CD 800A, CD 1250A, 1600A2799 3015+
17.7/450CD 800A, CD 1250A, 1600A2799 3019+

Options

OptionDescriptionAmpere RatingCatalog NumberNotes
3-pole Terminal Shrouds Kit (IP20)Line + load shroud side / front terminalsCD 125A, CD 160A, CD 200A4194 3013+
4-pole Terminal Shrouds Kit (IP20)Line + load shroud side / front terminalsCD 125A, CD 160A, CD 200A4194 4013+
Bridging barsFor 1 poleCD 125A, CD 160A, CD 200A4109 0019+One bridging bar required per pole
Auxiliary contacts1st NO.NC per position, 16ACD 125A, CD 160A, CD 200A4109 0021+
Auxiliary contacts2nd NO.NC per position, 16ACD 125A, CD 160A, CD 200A4109 0021+Mounted on the first aux. contact (part 4109 0021)
3-pole Terminal Shrouds Kit (IP20)Line + load shroud side / front terminalsCD 250A, CD 400A, CD 630A4194 3025+
4-pole Terminal Shrouds Kit (IP20)Line + load shroud side / front terminalsCD 250A, CD 400A, CD 630A4194 4025+
Bridging barsFor 1 poleCD 250A4109 0025+One bridging bar required per pole
Bridging barsFor 1 poleCD 400A4109 0039+One bridging bar required per pole
Bridging barsFor 1 poleCD 630A4109 0063+One bridging bar required per pole
Auxiliary contacts1st NO.NC per position, 16ACD 250A, CD 400A, CD 630A4109 0021+
Auxiliary contacts2nd NO.NC per position, 16ACD 250A, CD 400A, CD 630A4109 0021+Mounted on the first aux. contact (part 4109 0021)
3-pole Terminal ScreenLine + load shroud side / front terminalsCD 800A, CD 1250A2998 3080+
3-pole Terminal ScreenLine + load shroud side / front terminals1600A2998 3120+
4-pole Terminal ScreenLine + load shroud side / front terminalsCD 800A, CD 1250A2998 4080+
4-pole Terminal ScreenLine + load shroud side / front terminals1600A2998 4120+
Bridging barsFor 1 poleCD 800A4109 0080+One bridging bar required per pole
Bridging barsFor 1 poleCD 1250A4109 0120+One bridging bar required per pole
Bridging barsFor 1 pole1600A4409 0160+One bridging bar required per pole
Auxiliary contacts1st NO.NC per position, 16ACD 800A, CD 1250A4109 0021+
Auxiliary contacts1st NO.NC per position, 16A1600A4409 0021+
Auxiliary contacts2nd NO.NC per position, 16ACD 800A, CD 1250A4109 0021+Mounted on the first aux. contact (part 4109 0021 or 4409 0021)
Auxiliary contacts2nd NO.NC per position, 16A1600A4409 0022+Mounted on the first aux. contact (part 4109 0021 or 4409 0021)