Skip to main content

gRB-URB Series / 690V / Size 000

The gRB-URB Series / 690V / Size 000 is part of the Mersen (formerly Ferraz Shawmut) semiconductor fuses line, distributed by Gross Automation.

gRB-URB Series / 690V / Size 000

6,9 gRB-URB semiconductor protection fuses, DIN 000 (German standard): 500-690V AC, 20 to 400A, with or without blown fuse indication, or with trip indicator.

Specifications

SpecificationValue
RatingsAC: 500-690V AC, 20 TO 400A; UL Recognized; RoHS Compliant
FeaturesExtremely High Interrupting Rating Fuses: Protection of Power Semiconductors according to IEC 269. and EN 60269-.4; 500-690V Voltage Rating (Rating 20 to 400A); Full range protection; Improving safety and protection; Allows selective coordination; aR Class (URB Ratings 75 to 400A) According to VDE 636-23 and IEC 269.4; Two models according to BS 88-4 and EN 60 269.4 Standards: Z3 Drawing (74mm Between Axes) External open fuse with and without indicator.

Features

  • Extremely High Interrupting Rating Fuses: Protection of Power Semiconductors according to IEC 269. and EN 60269-.4
  • 500-690V Voltage Rating (Rating 20 to 400A)
  • Full range protection
  • Improving safety and protection
  • Allows selective coordination
  • aR Class (URB Ratings 75 to 400A) According to VDE 636-23 and IEC 269.4
  • Two models according to BS 88-4 and EN 60 269.4 Standards: Z3 Drawing (74mm Between Axes) External open fuse with and without indicator.

Ratings

  • AC: 500-690V AC, 20 TO 400A
  • UL Recognized
  • RoHS Compliant

Catalog Numbers

AmpsCatalog NumberRef #
166,9 GRB 000 PV 016+Y210609+
206,9 GRB 000 PV 020+Z210610+
256,9 GRB 000 PV 025+A210611+
326,9 GRB 000 PV 032+B210612+
406,9 GRB 000 PV 040+C210613+
506,9 GRB 000 PV 050+D210614+
636,9 GRB 000 PV 063+E210615+
806,9 GRB 000 PV 080+F210616+
1006,9 GRB 000 PV 100+G210617+
1256,9 GRB 000 PV 125+H210618+
806,9 URD 000 PV 0080+Q320059+
1006,9 URD 000 PV 0100+V320063+
1256,9 URD 000 PV 0125+X320065+
1606,9 URD 000 PV 0160+B320069+
2006,9 URD 000 PV 0200+D320071+
2506,9 URD 000 PV 0250+H320075+
3156,9 URD 000 PV 0315+M320079+
3505 URB 000 PV 350+R210626+
4005 URB 000 PV 400+S210627+
206,9 GRB 000 D08 / 020+D330030+
256,9 GRB 000 D08 / 025+E330031+
326,9 GRB 000 D08 / 032+F330032+
406,9 GRB 000 D08 / 040+G330033+
506,9 GRB 000 D08 / 050+H330034+
636,9 GRB 000 D08 / 063+J330035+
806,9 GRB 000 D08 / 080+A330073+
1006,9 GRB 000 D08 / 100+S330112+
1256,9 GRB 000 D08 / 125+T330113+
806,9 URB 000 D08 / 080+K330036+
1006,9 URB 000 D08 / 100+L330037+
1256,9 URB 000 D08 / 120+M330038+
1606,9 URB 000 D08 / 160+N330039+
2006,9 URB 000 D08 / 200+P330040+
2506,9 URB 000 D08 / 250+Q330041+
3156,9 URB 000 D08 / 315+R330042+
3505 URB 000 D08 / 350+V330114+
4005 URB 000 D08 / 400+D330191+
206,9 gRB 000 DO8V/020+P330017+
256,9 gRB 000 DO8V/025+Q330018+
326,9 gRB 000 DO8V/032+R330019+
406,9 gRB 000 DO8V/040+S330020+
506,9 gRB 000 DO8V/050+T330021+
636,9 gRB 000 DO8V/063+V330022+
806,9 gRB 000 DO8V/080+G330102+
1006,9 gRB 000 DO8V/100+Q330110+
1256,9 gRB 000 DO8V/125+R330111+
806,9 URB 000 DO8V/080+W330023+
1006,9 URB 000 DO8V/100+X330024+
1256,9 URB 000 DO8V/125+Y330025+
1606,9 URB 000 DO8V/160+Z330026+
2006,9 URB 000 DO8V/200+A330027+
2506,9 URB 000 DO8V/250+B330028+
3156,9 URB 000 DO8V/315+C330029+
3505 URB 000 DO8V/350+W330115+
4005 URB 000 DO8V/400+E330192+
206,9 gRB 000 DO8L/020+J330173+
256,9 gRB 000 DO8L/025+K330174+
326,9 gRB 000 DO8L/032+L330175+
406,9 gRB 000 DO8L/040+M330176+
506,9 gRB 000 DO8L/050+N330177+
636,9 gRB 000 DO8L/063+P330178+
806,9 gRB 000 DO8L/080+Q330179+
1006,9 gRB 000 DO8L/100+R330180+
1256,9 gRB 000 DO8L/125+S330181+
806,9 URB 000 DO8L/080+T330182+
1006,9 URB 000 DO8L/100+V330183+
1256,9 URB 000 DO8L/125+W330184+
1606,9 URB 000 DO8L/160+X330185+
2006,9 URB 000 DO8L/200+Y330186+
2506,9 URB 000 DO8L/250+Z330187+
3156,9 URB 000 DO8L/315+A330188+
3505 URB 000 DO8L/350+B330189+
4005 URB 000 DO8L/400+F330193+

Documentation