Skip to main content

BS88 Series / 690V / Size 000

The BS88 Series / 690V / Size 000 is part of the Mersen (formerly Ferraz Shawmut) general purpose fuses line, distributed by Gross Automation.

BS88 Series / 690V / Size 000

PROTISTOR® FUSES 500-690V AC gRB/URB FROM 20 TO 400A SIZE: 000

Specifications

SpecificationValue
RatingsAC: 690VAC 200kA I.R.; size 000, 20 through 100 Amperes. , 660VAC 120kA I.R.; size 000, 315 Amperes., 500VAC 120kA I.R.; size 000, 350 through 400 Amperes.; UL Recognized
FeaturesExtremely High Interrupting Rating Fuses: Protection of Power Semiconductors according to IEC 269. and EN 60269-.4; 500-690V Voltage Rating (Rating 20 to 400A); Full range protection; Improving safety and protection; Allows selective coordination; aR Class (URB Ratings 75 to 400A) According to VDE 636-23 and IEC 269.4; Two models according to BS 88-4 and EN 60 269.4 Standards: Z3 Drawing (74mm Between Axes) External open fuse with and without indicator

Features

  • Extremely High Interrupting Rating Fuses: Protection of Power Semiconductors according to IEC 269. and EN 60269-.4
  • 500-690V Voltage Rating (Rating 20 to 400A)
  • Full range protection
  • Improving safety and protection
  • Allows selective coordination
  • aR Class (URB Ratings 75 to 400A) According to VDE 636-23 and IEC 269.4
  • Two models according to BS 88-4 and EN 60 269.4 Standards: Z3 Drawing (74mm Between Axes) External open fuse with and without indicator

Ratings

  • AC: 690VAC 200kA I.R.; size 000, 20 through 100 Amperes. , 660VAC 120kA I.R.; size 000, 315 Amperes., 500VAC 120kA I.R.; size 000, 350 through 400 Amperes.
  • UL Recognized

Catalog Numbers

British Standard without open fuse indicator

AmpsCatalog NumberRef #
206,9gRB000BS88/020+T330044+
256,9gRB000BS88/025+V330045+
326,9gRB000BS88/032+W330046+
406,9gRB000BS88/040+X330047+
506,9gRB000BS88/050+Z330049+
636,9gRB000BS88/063+A330050+
806,9gRB000BS88/080+N330108+
1006,9gRB000BS88/100+H330103+
1256,9gRB000BS88/125+P330109+
756,9URB000BS88/075+B330051+
806,9URB000BS88/080+C330052+
1006,9URB000BS88/100+D330053+
1106,9URB000BS88/110+E330100+
1256,9URB000BS88/125+E330054+
1506,9URB000BS88/150+F330101+
1606,9URB000BS88/160+F330055+
2006,9URB000BS88/200+G330056+
2506,9URB000BS88/250+H330057+
3156,9URB000BS88/315+J330058+
3505URB000BS88/350+X330116+
4005URB000BS88/400+G330194+

British Standard with external open fuse trip-indicator

AmpsCatalog NumberRef #
206,9gRB000BS88P/020+Y330117+
256,9gRB000BS88P/025+Z330118+
326,9gRB000BS88P/032+A330119+
406,9gRB000BS88P/040+B330120+
506,9gRB000BS88P/050+C330121+
636,9gRB000BS88P/063+D330122+
806,9gRB000BS88P/080+E330123+
1006,9gRB000BS88P/100+F330124+
1256,9gRB000BS88P/125+G330125+
756,9URB000BS88P/075+H330126+
806,9URB000BS88P/080+J330127+
1006,9URB000BS88P/100+K330128+
1106,9URB000BS88P/110+L330129+
1256,9URB000BS88P/125+M330130+
1506,9URB000BS88P/150+N330131+
1606,9URB000BS88P/160+P330132+
2006,9URB000BS88P/200+Q330133+
2506,9URB000BS88P/250+R330134+
3156,9URB000BS88P/315+S330135+
3505URB000BS88P/350+T330136+
4005URB000BS88P/400+H330195+

Documentation

Distributing power? Gross Manufacturing, our UL 508A panel shop, builds power distribution and generator panels.