BS88 Series / 690V / Size 000
The BS88 Series / 690V / Size 000 is part of the Mersen (formerly Ferraz Shawmut) general purpose fuses line, distributed by Gross Automation.

PROTISTOR® FUSES 500-690V AC gRB/URB FROM 20 TO 400A SIZE: 000
Specifications
| Specification | Value |
|---|---|
| Ratings | AC: 690VAC 200kA I.R.; size 000, 20 through 100 Amperes. , 660VAC 120kA I.R.; size 000, 315 Amperes., 500VAC 120kA I.R.; size 000, 350 through 400 Amperes.; UL Recognized |
| Features | Extremely High Interrupting Rating Fuses: Protection of Power Semiconductors according to IEC 269. and EN 60269-.4; 500-690V Voltage Rating (Rating 20 to 400A); Full range protection; Improving safety and protection; Allows selective coordination; aR Class (URB Ratings 75 to 400A) According to VDE 636-23 and IEC 269.4; Two models according to BS 88-4 and EN 60 269.4 Standards: Z3 Drawing (74mm Between Axes) External open fuse with and without indicator |
Features
- Extremely High Interrupting Rating Fuses: Protection of Power Semiconductors according to IEC 269. and EN 60269-.4
- 500-690V Voltage Rating (Rating 20 to 400A)
- Full range protection
- Improving safety and protection
- Allows selective coordination
- aR Class (URB Ratings 75 to 400A) According to VDE 636-23 and IEC 269.4
- Two models according to BS 88-4 and EN 60 269.4 Standards: Z3 Drawing (74mm Between Axes) External open fuse with and without indicator
Ratings
- AC: 690VAC 200kA I.R.; size 000, 20 through 100 Amperes. , 660VAC 120kA I.R.; size 000, 315 Amperes., 500VAC 120kA I.R.; size 000, 350 through 400 Amperes.
- UL Recognized
Catalog Numbers
British Standard without open fuse indicator
| Amps | Catalog Number | Ref # |
|---|---|---|
| 20 | 6,9gRB000BS88/020+ | T330044+ |
| 25 | 6,9gRB000BS88/025+ | V330045+ |
| 32 | 6,9gRB000BS88/032+ | W330046+ |
| 40 | 6,9gRB000BS88/040+ | X330047+ |
| 50 | 6,9gRB000BS88/050+ | Z330049+ |
| 63 | 6,9gRB000BS88/063+ | A330050+ |
| 80 | 6,9gRB000BS88/080+ | N330108+ |
| 100 | 6,9gRB000BS88/100+ | H330103+ |
| 125 | 6,9gRB000BS88/125+ | P330109+ |
| 75 | 6,9URB000BS88/075+ | B330051+ |
| 80 | 6,9URB000BS88/080+ | C330052+ |
| 100 | 6,9URB000BS88/100+ | D330053+ |
| 110 | 6,9URB000BS88/110+ | E330100+ |
| 125 | 6,9URB000BS88/125+ | E330054+ |
| 150 | 6,9URB000BS88/150+ | F330101+ |
| 160 | 6,9URB000BS88/160+ | F330055+ |
| 200 | 6,9URB000BS88/200+ | G330056+ |
| 250 | 6,9URB000BS88/250+ | H330057+ |
| 315 | 6,9URB000BS88/315+ | J330058+ |
| 350 | 5URB000BS88/350+ | X330116+ |
| 400 | 5URB000BS88/400+ | G330194+ |
British Standard with external open fuse trip-indicator
| Amps | Catalog Number | Ref # |
|---|---|---|
| 20 | 6,9gRB000BS88P/020+ | Y330117+ |
| 25 | 6,9gRB000BS88P/025+ | Z330118+ |
| 32 | 6,9gRB000BS88P/032+ | A330119+ |
| 40 | 6,9gRB000BS88P/040+ | B330120+ |
| 50 | 6,9gRB000BS88P/050+ | C330121+ |
| 63 | 6,9gRB000BS88P/063+ | D330122+ |
| 80 | 6,9gRB000BS88P/080+ | E330123+ |
| 100 | 6,9gRB000BS88P/100+ | F330124+ |
| 125 | 6,9gRB000BS88P/125+ | G330125+ |
| 75 | 6,9URB000BS88P/075+ | H330126+ |
| 80 | 6,9URB000BS88P/080+ | J330127+ |
| 100 | 6,9URB000BS88P/100+ | K330128+ |
| 110 | 6,9URB000BS88P/110+ | L330129+ |
| 125 | 6,9URB000BS88P/125+ | M330130+ |
| 150 | 6,9URB000BS88P/150+ | N330131+ |
| 160 | 6,9URB000BS88P/160+ | P330132+ |
| 200 | 6,9URB000BS88P/200+ | Q330133+ |
| 250 | 6,9URB000BS88P/250+ | R330134+ |
| 315 | 6,9URB000BS88P/315+ | S330135+ |
| 350 | 5URB000BS88P/350+ | T330136+ |
| 400 | 5URB000BS88P/400+ | H330195+ |