Skip to main content

A70P / 700V

The A70P / 700V is part of the Mersen (formerly Ferraz Shawmut) semiconductor fuses line, distributed by Gross Automation.

A70P / 700V

A70P Amp-trap® Form 101 Semiconductor Protection fuses were developed for higher voltage AC and DC drives, UPS systems, reduced voltage motor starters and similar applications where lower I2t and superior reliability were needed. A70P is a very popular fuse, available in a wide range of ratings.

Specifications

SpecificationValue
RatingsAC: 700VAC, 10A to 1000A, 100kA I.R.; AC: 650VDC, 10A to 800A, 100kA I.R.; UL Recognized Component; AC: Guide No. JFHR2; DC: Tested to UL Standard 198L parameters; Some Ratings RoHS Compliant; Protection of 700V or less DC drives, UPS, inverters, reduced voltage starters, etc.
FeaturesControlled arc voltage reduces stress to circuit components during fuse clearing; Choice of mounting types helps in equipment design; Very Fast Acting; Current limiting; Indicator Options Available

Features

  • Controlled arc voltage reduces stress to circuit components during fuse clearing
  • Choice of mounting types helps in equipment design
  • Very Fast Acting
  • Current limiting
  • Indicator Options Available

Ratings

  • AC: 700VAC, 10A to 1000A, 100kA I.R.
  • AC: 650VDC, 10A to 800A, 100kA I.R.
  • UL Recognized Component
  • AC: Guide No. JFHR2
  • DC: Tested to UL Standard 198L parameters
  • Some Ratings RoHS Compliant
  • Protection of 700V or less DC drives, UPS, inverters, reduced voltage starters, etc.

Catalog Numbers

How to choose

Each catalog number is one fuse; the number spells out its choices:

  1. Amps: the Amps column (the number after A70P).
  2. Mounting: -1 is a ferrule fuse; -4 has bolt-in blades.
  3. Indicator: TI at the end adds a trigger indicator, TA a trigger actuator (integral blown-fuse indicators).

Reading a number: A70P300-4TI is rated 700 V, style P, 300 A, bolt-in blades, with trigger indicator.

Source: Mersen A70P catalog (PDF), catalog numbering system on page 1

AmpsCatalog Number
10A70P10-1+
10A70P10-4+
15A70P15-1+
15A70P15-4+
20A70P20-1+
25A70P25-1+
25A70P25-4+
30A70P30-1+
30A70P30-4+
35A70P35-4+
40A70P40-4+
40A70P40-4TA+
40A70P40-4TI+
50A70P50-4+
60A70P60-4+
60A70P60-4TA+
60A70P60-4TI+
70A70P70-4+
70A70P70-4TI+
80A70P80-4+
80A70P80-4TA+
80A70P80-4TI+
90A70P90-4+
100A70P100-4+
100A70P100-4TA+
125A70P125-4+
125A70P125-4TA+
150A70P150-4+
150A70P150-4TA+
150A70P150-4TI+
175A70P175-4+
200A70P200-4+
200A70P200-4TA+
200A70P200-4TI+
225A70P225-4+
250A70P250-4+
250A70P250-4TA+
250A70P250-4TI+
300A70P300-4+
350A70P350-4+
400A70P400-4+
400A70P400-4TA+
400A70P400-4TI+
450A70P450-4+
500A70P500-4+
600A70P600-4+
600A70P600-4TA+
600A70P600-4TI+
700A70P700-4+
700A70P700-4TI+
800A70P800-4+
800A70P800-4TI+
900A70P900-4+
1000A70P1000-4+
1200A7OP1200-4+

Documentation

Fuses and breakers set your panel's short-circuit rating. See how our UL 508A shop rates it.