67000 Series (Aluminum Connector)
The 67000 Series (Aluminum Connector) is part of the Mersen (formerly Ferraz Shawmut) power distribution line, distributed by Gross Automation.

Ferraz Shawmut Power Distribution Blocks afford a safe, convenient way of splicing cables, splitting primary power into a variety of secondary circuits or providing a fixed junction tap-off point. Power block options include up to 7 primary connections with up to 30 secondary connections.
Specifications
| Specification | Value |
|---|---|
| Ratings | AC: Ampere ratings from 170 to 2660A 600V rated; Most sizes are UL Recognized Component - Guide XCFR2, File E73571; Most sizes are CSA Certified: Class 6228, File 69363; RoHS Compliant; Box and stud terminations for copper and /or aluminum cables |
| Features | Adder Poles All series have optional adder poles which snap onto the 1, 2 or 3- pole blocks and lock together to form as many total poles as required. Adder poles with a variety of terminations can be combined to match special wire size combinations.; Wire Connectors Standard aluminum box connectors accommodate aluminum or copper wire, 1 conductor per opening. Standard copper box connections are for copper wire only, 1 conductor per opening. Connectors are all 1 piece and tin plated.; Insulators Insulators are virtually unbreakable, glass-filled polycarbonate on all series. "See-Through" Safety Covers are available which give greater safety and provide Service Entrance ratings for large series blocks. |
Features
- Adder Poles All series have optional adder poles which snap onto the 1, 2 or 3- pole blocks and lock together to form as many total poles as required. Adder poles with a variety of terminations can be combined to match special wire size combinations.
- Wire Connectors Standard aluminum box connectors accommodate aluminum or copper wire, 1 conductor per opening. Standard copper box connections are for copper wire only, 1 conductor per opening. Connectors are all 1 piece and tin plated.
- Insulators Insulators are virtually unbreakable, glass-filled polycarbonate on all series. "See-Through" Safety Covers are available which give greater safety and provide Service Entrance ratings for large series blocks.
Ratings
- AC: Ampere ratings from 170 to 2660A 600V rated
- Most sizes are UL Recognized Component - Guide XCFR2, File E73571
- Most sizes are CSA Certified: Class 6228, File 69363
- RoHS Compliant
- Box and stud terminations for copper and /or aluminum cables
Catalog Numbers
How to choose
Each row is one wire combination; pick your row, then the number of poles.
- Connection: Box to Box or Box to Stud (the lists below).
- Wire: the primary and secondary wire range (AWG/kcmil) or stud size, with the openings or studs per pole in brackets. These aluminum connectors take aluminum or copper wire; the 66000 series has copper connectors, for copper wire only.
- Poles: a 1, 2 or 3 pole block, or an adder pole, which snaps onto a 1, 2 or 3 pole block; adder poles lock together to form as many poles as required.
Ampere ratings are based on NEC Table 310-16 for 75 °C copper wire.
SCCR: short-circuit current rating 100 kA with a correctly sized fuse, except adder blocks.
A * after a wire range: copper wire only.
Source: Mersen Intermediate Series power distribution blocks (PDF), page 2
Box to Box
| Primary (openings) | Secondary (openings) | Amps | Adder | 1 Pole | 2 Pole | 3 Pole | SCCR |
|---|---|---|---|---|---|---|---|
| 2/0-#14 (1) | 2/0-#14 (1) | 175 | 67050+ | 67051+ | 67052+ | 67053+ | 100 kA |
| 2/0-#14 (1) | #2-14 (4) | 175 | 67570+ | 67571+ | 67572+ | 67573+ | 100 kA |
| 2/0-#14 (1) | #2-14 (6) | 175 | 67560+ | 67561+ | 67562+ | 67563+ | 100 kA |
| 2/0-#14 (1) | #2-14 (8) | 175 | 67580+ | 67581+ | 67582+ | 67583+ | 100 kA |
| 2/0-#14 (1) | #6-14 (10) | 175 | 67590+ | 67591+ | 67592+ | 67593+ | 100 kA |
| 2/0-#14 (1) | #10-14* (12) | 175 | 67110+ | 67111+ | 67112+ | 67113+ | 100 kA |
| 350-#6 (1) | 350-#6 (1) | 310 | 67000+ | 67001+ | 67002+ | 67003+ | 100 kA |
| 350-#6 (1) | 2/0-#14 (2) | 310 | 67010+ | 67011+ | 67012+ | 67013+ | 100 kA |
| 350-#6 (1) | #2-14 (4) | 310 | 67670+ | 67671+ | 67672+ | 67673+ | 100 kA |
| 350-#6 (1) | #2-14 (6) | 310 | 67660+ | 67661+ | 67662+ | 67663+ | 100 kA |
| 350-#6 (1) | #2-14 (8) | 310 | 67630+ | 67631+ | 67632+ | 67633+ | 100 kA |
| 350-#6 (1) | #6-14 (10) | 310 | 67650+ | 67651+ | 67652+ | 67653+ | 100 kA |
| 350-#6 (1) | #10-14* (15) | 310 | 67620+ | 67621+ | 67622+ | 67623+ | 100 kA |
| 500-#4 (1) | 500-#4 (1) | 380 | 67400+ | 67401+ | 67402+ | 67403+ | 100 kA |
| 500-#4 (1) | 4/0-#6 (2) | 380 | 67420+ | 67421+ | 67422+ | 67423+ | - |
| 500-#4 (1) | 2/0-#14 (4) | 380 | 67410+ | 67411+ | 67412+ | 67413+ | 100 kA |
| 500-#4 (1) | #2-14 (6) | 380 | 67460+ | 67461+ | 67462+ | 67463+ | 100 kA |
| 500-#4 (1) | #2-14 (8) | 380 | 67430+ | 67431+ | 67432+ | 67433+ | 100 kA |
| 500-#4 (1) | #6-14 (10) | 380 | 67480+ | 67481+ | 67482+ | 67483+ | 100 kA |
| 500-#4 (1) | #10-14* (18) | 380 | 67490+ | 67491+ | 67492+ | 67493+ | 100 kA |
| 500-#4 (1) | 350-#6 (1) & #2-14 (3) | 380 | 67450+ | 67451+ | 67452+ | 67453+ | 100 kA |
| 2/0-#14 (2) | 2/0-#14 (2) | 350 | 67020+ | 67021+ | 67022+ | 67023+ | 100 kA |
| 2/0-#14 (2) | #2-14 (6) | 350 | 67510+ | 67511+ | 67512+ | 67513+ | 100 kA |
| 2/0-#14 (2) | #2-14 (8) | 350 | 67610+ | 67611+ | 67612+ | 67613+ | 100 kA |
| 2/0-#14 (2) | #6-14 (10) | 350 | 67530+ | 67531+ | 67532+ | 67533+ | 100 kA |
| 2/0-#14 (2) | #10-14* (15) | 350 | 67550+ | 67551+ | 67552+ | 67553+ | 100 kA |
| 4/0-#6 (2) | 4/0-#6 (2) | 460 | 67520+ | 67521+ | 67522+ | 67523+ | - |
| 4/0-#6 (2) | #2-14 (6) | 460 | 67540+ | 67541+ | 67542+ | 67543+ | 100 kA |